Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Pesqui. vet. bras ; 39(3): 214-220, Mar. 2019. tab, ilus
Article in English | LILACS, VETINDEX | ID: biblio-1002798

ABSTRACT

The objective of this study was to evaluate the quality and recovery from anesthesia promoted by the tiletamine-zolazepam (TZ) combination administered intravenously (IV) continuously in bitches pre-medicated with acepromazine. Eight cross-bred, clinically healthy bitches weighing 13.7 ±1.9kg on average were used in this study. After a food fast of 12 h and a water fast of four hours, the animals were treated with acepromazine (0.1mg/kg, intramuscular) and, after 15 minutes, anesthesia was induced with a combination of tiletamine-zolazepam (2mg/kg, IV) immediately followed by continuous IV infusion thereof at a dose of 2mg/kg/h for 60 min. The following parameters were measured in all animals immediately before administration of acepromazine (M15), immediately before anesthetic induction (M0), and at 5, 10, 20, 30, 40, 50, and 60 min after initiation of continuous infusion (M5, M10, M20, M30, M40, M50, and M60): electrocardiography (ECG), heart rate (HR), mean arterial pressure (MAP), respiratory rate (RR), body temperature (BT), and arterial hemogasometry, with the last performed only at experimental times M15, M0, M30, and M60. A subcutaneous electrical stimulator was used to evaluate the degree of analgesia. Myorelaxation and quality of anesthetic recovery were also assessed, classifying these parameters as excellent, good, and poor. Anesthetic recovery time was recorded in minutes. HR increased significantly at time M10 in relation to that at M-15, and at times M5, M10, M40, and M50 in relation to that at M0. MAP decreased significantly at M20 and M30 compared with the baseline. BT decreased significantly at M50 compared with that at M0, but no hypothermia was observed. RR showed significant reduction at M5, M10, and M20 in relation to that at M-15, and at M5 and M10 in relation to that at M0, and bradypnoea was observed during the first 20 min after anesthetic induction. Significant decreases in the PR interval at times M10, M40, and M50 were observed in relation to that at M15. Amplitude of the R wave showed significant decrease at M20 compared with that at M-15. In the other ECG parameters, no significant difference was observed between the times evaluated. Hemogasometric parameters and analgesia did not show significant alterations. Myorelaxation and quality of anesthetic recovery were considered excellent. Recovery time was 15.1±7.7 min for positioning of sternal decubitus and 45.5±23.1 minutes for return of ambulation. Continuous IV administration of TZ combination does not produce satisfactory analgesia and does not cause severe cardiorespiratory and hemogasometric effects in bitches pre-medicated with acepromazine.(AU)


Objetivou-se avaliar a qualidade e a recuperação da anestesia promovida pela associação tiletamina-zolazepam, administrada por via intravenosa (IV) contínua, em cadelas pré-medicadas com acepromazina. Foram utilizadas oito cadelas, sem raças definidas, clinicamente sadias, pesando em média 13,7±1,9kg. Após jejum alimentar de 12 horas e hídrico de quatro horas, os animais foram medicados com acepromazina (0,1mg/kg, via intramuscular) e, após 15 minutos, a anestesia foi induzida com a associação tiletamina-zolazepam (2mg/kg, IV) seguida imediatamente pela infusão IV contínua da mesma, na dose de 2mg/kg/h, durante 60 minutos. Os parâmetros que foram mensurados em todos os animais, imediatamente antes da administração da acepromazina (M-15), imediatamente antes da indução anestésica (M0) e, aos 5, 10, 20, 30, 40, 50 e 60 minutos após o início da infusão contínua (M5, M10, M20, M30, M40, M50 e M60) foram os seguintes: eletrocardiografia (ECG), frequência cardíaca (FC), pressão arterial média (PAM), frequência respiratória (f), temperatura corpórea (TC) e hemogasometria arterial, esta sendo realizada apenas nos momentos M-15, M0, M30 e M60. Para avaliação do grau de analgesia foi empregado um estimulador elétrico subcutâneo. Também se avaliou o miorrelaxamento e a qualidade da recuperação anestésica, classificando estes parâmetros em: excelente, bom e ruim. O tempo de recuperação anestésica foi registrado em minutos. A FC aumentou significativamente no momento M10 em relação ao M-15, e nos momentos M5, M10, M40 e M50 em relação ao M0. A PAM diminuiu significativamente em M20 e M30 em comparação ao valor basal. A TC diminuiu significativamente em M50 em comparação ao M0, mas não foi observada hipotermia. A f apresentou uma redução significativa nos momentos M5, M10 e M20 em relação ao M-15, e em M5 e M10 em relação ao M0, sendo observado bradipneia durante os primeiros 20 minutos após a indução anestésica. Foram observadas diminuições significativas do intervalo PR nos momentos M10, M40 e M50, em relação ao M-15. A amplitude da onda R apresentou diminuição significativa em M20 em comparação ao M-15. Nos demais parâmetros da ECG não houve diferença significativa entre os momentos avaliados. Os parâmetros hemogasométricos e a analgesia não apresentaram alterações significativas. O miorrelaxamento e a qualidade da recuperação anestésica foram considerados excelentes. O período de recuperação foi de 15,1±7,7 minutos para posicionamento do decúbito esternal e 45,5±23,1 minutos para retorno da deambulação. A administração intravenosa contínua de tiletamina-zolazepam não produz analgesia satisfatória e não causa efeitos cardiorrespiratórios e hemogasométricos severos, em cadelas pré-tratadas com acepromazina.(AU)


Subject(s)
Animals , Female , Dogs , Tiletamine/pharmacology , Zolazepam/pharmacology , Anesthesia Recovery Period , Respiratory Rate/drug effects , Heart Rate/drug effects , Adjuvants, Anesthesia , Anesthesia, Intravenous/veterinary , Acepromazine/pharmacology
2.
Rev. bras. anestesiol ; 68(4): 329-335, July-Aug. 2018. tab
Article in English | LILACS | ID: biblio-958310

ABSTRACT

Abstract Background and objectives The primary aim was to determine risk factors for flumazenil administration during postanesthesia recovery. A secondary aim was to describe outcomes among patients who received flumazenil. Methods Patients admitted to the postanesthesia recovery room at a large, academic, tertiary care facility after surgery under general anesthesia from January 1, 2010, to April 30, 2015, were identified and matched to 2 controls each, by age, sex, and surgical procedure. Flumazenil was administered in the recovery phase immediately after general anesthesia, according to the clinical judgment of the anesthesiologist. Demographic, procedural, and outcome data were extracted from the electronic health record. Conditional logistic regression, accounting for the 1:2 matched-set case-control study designs, was used to assess characteristics associated with flumazenil use. Results The incidence of flumazenil administration in the postanesthesia care unit was 9.9 per 10,000 (95% CI, 8.4-11.6) general anesthetics. History of obstructive sleep apnea (Odds Ratio [OR] = 2.27; 95% CI 1.02-5.09), longer anesthesia (OR = 1.13; 95% CI 1.03-1.24 per 30 minutes), use of total intravenous anesthesia (OR = 6.09; 95% CI 2.60-14.25), and use of benzodiazepines (OR = 8.17; 95% CI 3.71-17.99) were associated with risk for flumazenil administration. Among patients who received midazolam, cases treated with flumazenil received a higher median (interquartile range) dose than controls: 3.5 mg (2.0-4.0 mg) vs. 2.0 mg (2.0-2.0 mg), respectively (p < 0.001). Flumazenil use was correlated with a higher rate of unanticipated noninvasive positive pressure ventilation, longer postanesthesia care unit stay, and increased rate of intensive care unit admissions. Conclusions Patients who required flumazenil postoperatively had received a higher dosage of benzodiazepines and utilized more postoperative health care resources. More conservative perioperative use of benzodiazepines may improve postoperative recovery and use of health care resources.


Resumo Justificativa e objetivos Determinar os fatores de risco da administração de flumazenil durante a recuperação pós-anestésica e descrever os desfechos entre os pacientes que receberam flumazenil. Métodos Os pacientes admitidos em sala de recuperação pós-anestésica de um grande centro universitário em setor terciário de cuidados pós-cirurgia sob anestesia geral entre 1° de janeiro de 2010 e 30 de abril de 2015 foram identificados e pareados com dois controles cada por idade, sexo e procedimento cirúrgico. Flumazenil foi administrado na fase de recuperação imediatamente após a anestesia geral, de acordo com a avaliação clínica do anestesiologista. Os dados demográficos, dos procedimentos e dos desfechos foram extraídos do registro eletrônico de saúde. A regressão logística condicional para os desenhos do estudo de caso-controle pareado em 1:2 foi usada para avaliar as características associadas ao uso de flumazenil. Resultados A incidência da administração de flumazenil em sala de recuperação pós-anestésica foi de 9,9 por 10.000 (95% IC: 8,4-1,6) anestesias gerais. História da apneia obstrutiva do sono (razão de chances [OR] = 2,27; IC 95%: 1,02-5,09), anestesia de longa duração (OR = 1,13; IC 95%: 1,03-1,24 por 30 minutos), uso de anestesia intravenosa total (OR = 6,09; IC de 95%: 2,60-14,25) e uso de benzodiazepínicos (OR = 8,17; IC 95%: 3,71-17,99) foram associados a risco para a administração de flumazenil. Entre os pacientes que receberam midazolam, os casos tratados com flumazenil receberam uma dose mediana mais alta (intervalo interquartil) do que os controles: 3,5 mg (2,0-4,0 mg) vs. 2,0 mg (2,0-2,0 mg), respectivamente (p < 0,001). O uso de flumazenil foi correlacionado com uma taxa maior não prevista de ventilação não invasiva com pressão positiva, permanência mais longa em sala de recuperação pós-anestésica e aumento da taxa de admissões em unidade de terapia intensiva. Conclusão Os pacientes que precisaram de flumazenil no pós-operatório receberam uma dose maior de benzodiazepínicos e usaram mais recursos de cuidados da saúde no pós-operatório. O uso mais conservador de benzodiazepínicos no período perioperatório pode melhorar a recuperação e o uso de recursos de cuidados da saúde no pós-operatório.


Subject(s)
Humans , Postoperative Complications , Anesthesia Recovery Period , Flumazenil/administration & dosage , Receptors, GABA-A/administration & dosage , Case-Control Studies , Retrospective Studies
3.
J. bras. psiquiatr ; 67(2): 80-86, jan.-jun. 2018. tab
Article in Portuguese | LILACS | ID: biblio-893952

ABSTRACT

RESUMO Objetivo Conhecer as modificações do padrão do sono em insones usuários crônicos de benzodiazepínicos (BZDs) após introdução da trazodona. Métodos Em um grupo de 11 pacientes, foi estabelecido esquema para retirada gradual do BZD com introdução progressiva da trazodona. Foram realizadas duas polissonografias, sendo a primeira com dose de BZD habitual do paciente e a segunda após supensão do BZD e com 150 mg de trazodona de liberação prolongada. Questionários de qualidade do sono (Pittsburgh), sonolência diurna (Epworth) e sintomas depressivos (Hamilton) e ansiosos (Beck) foram aplicados. Resultados Cinco indivíduos concluíram o estudo, tendo sido acompanhados por pelo menos seis semanas. Nesses pacientes, a trazodona aumentou significativamente a eficiência do sono e sono REM e diminuiu o tempo desperto após início do sono. Houve melhora da qualidade do sono, porém não houve alteração dos sintomas depressivos e ansiosos. Conclusão Trazodona de liberação prolongada demonstrou ser uma opção terapêutica para insones usuários crônicos de BZDs com retirada eficaz do ansiolítico. Houve melhora na qualidade do sono por questionário e polissonografia. Maior número de pacientes será necessário para determinar os benefícios da trazodona nesse tipo de intervenção.


ABSTRACT Objective To know the modifications of the sleep pattern in chronic benzodiazepine users after the introduction of trazodone. Methods In a group of 11 patients, a gradual withdrawal of benzodiazepine (BZD) was introduced with progressive introduction of trazodone. Two polysomnograms were performed, the first with BZD usual dose of the patient and the second after BZD suppression and with 150 mg of prolonged release trazodone. Sleep quality questionnaires (Pittsburgh), daytime sleepiness (Epworth) and depressive (Hamilton) and anxious (Beck) symptoms were applied. Results Five subjects completed the study and were followed up for at least six weeks. In these patients, trazodone significantly increased sleep efficiency and REM sleep and decreased wakefulness after sleep onset. There was an improvement in sleep quality, but there was no change in depressive and anxious symptoms. Conclusion Prolonged release trazodone has been shown to be a therapeutic option for chronic insomnia patients with benzodiazepines with effective withdrawal of the anxiolytic drug. There was improvement in sleep quality by questionnaire and polysomnography. More patients will be needed to determine the benefits of trazodone in this type of intervention.

4.
Rev. bras. ciênc. vet ; 24(1): 3-7, jan.-mar.2017. il.
Article in Portuguese | LILACS | ID: biblio-966790

ABSTRACT

Frequentemente o médico-veterinário é requisitado para realização de diversos procedimentos em aves, os quais geralmente necessitam de sedação ou anestesia geral. Este trabalho teve como objetivo comparar os efeitos sedativos do midazolam (5 mg.kg-1) associado ou não ao butorfanol (1 mg.kg-1) pelas vias de administração intranasal ou intramuscular. Sete periquitos australianos foram submetidos a quatro tratamentos em delineamento do tipo crossover com 15 dias de intervalo. Foram avaliados os períodos de latência, tempos de decúbito dorsal, tempos de sedação, tempos de recuperação, grau de sedação e qualidade de recuperação. Os resultados paramétricos foram avaliados por análise de variância de uma via seguida por teste de Student- Newman-Keuls e os dados não paramétricos foram submetidos ao teste Kruskal-Wallis ambos com 5% de significância. A técnica intranasal demonstrou melhores graus de sedação; no entanto, concluiu-se que ambos os protocolos e as vias de administração avaliados são seguras e viáveis para sedação em periquito australiano.


Often veterinarians have attended various species of birds to perform clinical procedures, which require sedation or general anesthesia. The aim of this study was compare the intranasal or intramuscular sedative effects of midazolam (5 mg.kg-1) with or without butorphanol (1 mg.kg-1). Seven budgerigards (Melopsitacus undulates) were submitted in a crossover design to four treatments. The procedures were performed with 15 days washout. Were evaluated the on set time, dorsal recumbency time duration, total sedation period, total recovery time, sedation degree and recovery quality. The parametric results were analised by one way ANOVA following Student-Newman-Keuls test and non-parametric datas were submitted to Kruskal-Wallis test, both with 5% significance. The intranasal technical demonstrates best degrees of sedation, however, this study concluded that both protocols and the administration routes are safe and viable for sedation in budgerigards


Subject(s)
Animals , Poultry , Midazolam , Intramuscular Absorption , Nasal Absorption
5.
Arq. bras. med. vet. zootec ; 66(1): 109-115, fev. 2014. ilus, tab
Article in Portuguese | LILACS | ID: lil-704013

ABSTRACT

Avaliaram-se os efeitos da acepromazina isolada ou associada ao diazepam em asininos. Cinco asininos foram submetidos a dois protocolos anestésicos: os do grupo acepromazina (AC) receberam acepromazina, 0,1mg/kg/IV, e os do grupo acepromazina-diazepam (ACD), acepromazina na mesma dose e via do AC, associada ao diazepam, 0,1mg/kg/IV. Foram mensuradas as frequências cardíaca (FC) e respiratória (FR) e a temperatura retal (TR) e analisadas variáveis eletrocardiográficas, tranquilização, período de latência, início do prolapso peniano e grau de ataxia. A tranquilização iniciou-se aos 10,4±0,9 minutos nos asininos do AC e aos 4,8±1,1 nos do ACD. Ocorreu prolapso peniano aos 4,2±1,3min no AC e aos 2,7±0,4 no ACD. A FC elevou-se aos 15 e 30min no AC. Não ocorreu variação significativa nas variáveis eletrocardiográficas e na temperatura retal. A FR diminuiu no AC a partir de 60min e no ACD a partir de 30min. A distância focinho-solo reduziu-se significativamente em ambos os grupos e nos momentos a partir de 15min. Concluiu-se que a acepromazina promove tranquilização discreta, e a adição do diazepam potencializa a tranquilização, diminui o período de latência e aumenta a ataxia.


The effects of acepromazine isolated or associated with diazepam were evaluated in five donkeys were underwent in two anesthetic protocols, in the acepromazine group (AC), animals received acepromazine (0.1mg/kg/IV) and in acepromazine-diazepam group (ACD), acepromazine at the same dose and route of AC, associated with diazepam (0.1 mg/kg/IV). Heart frequency (HR), respiratory frequency (RF) and rectal temperature (RT) were measured and electrocardiographic variables analyzed, in addition to tanquilization, latency, beginning of the penile prolapse and degree of ataxia. The tanquilization began at 10.4±0.9 minutes (min) in the AC donkeys and 4.8±1.1 in ACD. Penile prolapse occurred at 4.2±1.3 minutes in AC and 2.7±0.4 in ACD. The HR increased to 15 and 30min. Electrocardiographic parameters and rectal temperature not varied significantly. RF decreased from AC in 60min and 30min from ACD. The muzzle-to-ground distance reduced significantly in both groups and at times from 15min. It was concluded that the acepromazine promotes discreet tanquilization and the adition of diazepam potentiates the tranquilization, decreases the latency period and increases ataxia caused by acepromazine.


Subject(s)
Animals , Anesthesiology/methods , Diazepam/pharmacology , Preanesthetic Medication/methods , Ruminants
6.
Braz. j. pharm. sci ; 50(2): 251-256, Apr-Jun/2014. tab, graf
Article in English | LILACS | ID: lil-722188

ABSTRACT

Flunitrazepam (FNZ) is a sedative benzodiazepine prescribed for the short-term treatment of insomnia. However, there are concerns regarding possible carcinogenic or genotoxic effects of this medicine. Thus, the aim of this study was to evaluate the cytotoxic, clastogenic and aneugenic effects of FNZ in hepatoma cells from Rattus norvegicus (HTC) in vitro and in bone marrow cells of Wistar rats in vivo. These effects were examined in vitro following treatment with 0.2, 1.0, 5.0 or 10 μg/mL FNZ using a micronucleus test with a cytokinesis block or in vivo using a chromosomal aberration test following treatment with 7, 15 or 30 μg/mL/kg body weight. The results showed that the benzodiazepine concentrations tested were not cytotoxic, aneugenic or clastogenic. However, considering the adverse effects of using this benzodiazepine, more studies are required.


Flunitrazepam (FNZ) é um sedativo benzodiazepínico prescrito para o tratamento da insônia em curto prazo. Entretanto, existe a preocupação com relação aos possíveis efeitos carcinogênicos ou genotóxicos causados por este fármaco. Então, o objetivo deste estudo foi avaliar os efeitos citotóxicos, clastogênicos e aneugênicos do FNZ em células de hepatoma de Rattus norvegicus (HTC) in vitro e em células de medula óssea de ratos Wistar in vivo. Foram testadas as concentrações de 0,2, 1,0 e 10 μg/mL de FNZ pelo teste do micronúcleo com bloqueio de citocinese in vitro e 7, 15 e 30 μg/mL/kg de peso corpóreo para o teste de aberração cromossômica in vivo. Os resultados mostraram que as concentrações do benzodiazepínico testadas não foram citotóxicas, aneugênicas ou clastogênicas. Entretanto, considerando os efeitos adversos do uso deste benzodiazepínico, mais estudos são necessários.


Subject(s)
Rats , In Vitro Techniques/instrumentation , Cytotoxins/classification , Flunitrazepam/analysis , Chromosome Disorders , Aneugens , Mutagens
7.
Ciênc. rural ; 42(12): 2206-2212, dez. 2012. tab
Article in Portuguese | LILACS | ID: lil-658050

ABSTRACT

Com este estudo objetivou-se avaliar o efeito cardiorrespiratório e a qualidade da anestesia e da recuperação pós-anestésica decorrentes da associação cetamina e xilazina seguida da infusão contínua intravenosa (IV) de midazolam isolado ou associado ao fentanil, em suínos. Foram avaliadas 10 porcas adultas, da raça Landrace, com peso médio de 170±4kg, submetidas à endoscopia. Todos os animais foram medicados pela via intramuscular com cetamina (4mg kg-1) associada à xilazina (2mg kg-1). Vinte minutos após, foi realizado um bolus IV de cetamina (2mg kg-1), seguida da infusão contínua IV de midazolam (0,5mg kg-1h-1 GM, n=5), ou midazolam (0,25mg kg-1h-1) associado ao fentanil (4µg kg-1 h-1 GMF, n=5). Foram avaliados: frequência cardíaca (FC) e ritmo cardíaco, pressão arterial sistólica (PAS), temperatura retal (T), frequência respiratória (f), variáveis hemogasométricas (PaO2, PaCO2, pH, HCO3-, SaO2), qualidade da anestesia e qualidade e tempo da recuperação anestésica (RA). A análise estatística foi realizada por meio de análise de variância, teste de Tukey e o teste não paramétrico de Mann-Whitney (P<0,05). A qualidade da anestesia foi semelhante entre os tratamentos, sendo possível a realização da endoscopia em ambos os grupos. Os parâmetros cardiorrespiratórios, bem como os gases sanguíneos, o pH, o bicarbonato e a saturação da oxihemoglobina não variaram entre os diferentes tratamentos. O tempo de recuperação anestésica foi de 98±15 e 79±17 minutos no GM e GMF, respectivamente, sem diferença entre os grupos. A qualidade da RA não diferiu significativamente entre os grupos. Conclui-se que ambos os tratamentos determinaram estabilidade cardiorrespiratória e foram satisfatórios para a realização de endoscopia em suínos. No entanto, apesar da ausência de diferença estatística, menor tempo de RA foi observado nos animais tratados com a infusão contínua de midazolam associado ao fentanil.


The aim of this study was to evaluate the cardiopulmonary effects, the quality of anesthesia and the post-anesthetic recovery of ketamine and xylazine premedication following intravenous (IV) continuous rate infusion of midazolam alone or in combination with fentanyl, in swine. Ten Landrace adult pigs that underwent endoscopy were evaluated. All pigs were premedicated with ketamine (4mg kg-1) and xylazine (2mg kg-1) by intramuscular administration. After twenty minutes, intravenous ketamine (2mg kg-1) was injected, following IV continuous rate infusion of midazolam (0.5mg kg-1 h-1 GM, n=5) or midazolam (0.25mg kg-1 h-1) plus fentanyl (4µg kg-1 h¹ GMF, n=5). Heart and respiratory rates, systolic arterial blood pressure, rectal temperature, arterial blood gases, quality of anesthesia and recovery, and time for recovery were investigated. Statistical analysis was performed with One-Way ANOVA, Tukey test and Mann-Whitney test (P<0.05). The quality of anesthesia was similar between treatments, and endoscopy was able to be performed in both groups. Cardiopulmonary variables and blood gases did not differ between groups. The recovery time was 98±15 and 79±17 minutes in GM and GMF, respectively, without significant difference between treatments. The quality of recovery did not differ between groups. The results allowed us to conclude that both treatments provide cardiopulmonary stability and were satisfactory to swine endoscopy. However, despite of absence of significant difference, shorter time of recovery was observed with midazolam/fentanyl infusion.

8.
Medicina (Guayaquil) ; 13(4): 257-262, sept. 2008.
Article in Spanish | LILACS | ID: lil-617688

ABSTRACT

Tipo de estudio: clínico experimental, aleatorio controlado de tipo doble ciego y cruzado. Objetivos: determinar si el uso profiláctico de benzodiazepínicos mejora las condiciones en las que se ejecutan los procedimientos quirúrgicos. Materiales y métodos: se estudió los efectos hallados en las 20 extracciones dentales que fueron realizadas en los pacientes hipertensos esenciales controlados, en las cuales se analizaron las variables: presión arterial sistólica y diastólica, duración del acto quirúrgico y estado general del paciente. Resultados: al comparar el mayor incremento de la presión arterial sistólica del grupo fármaco y grupo placebo observamos una diferencia de 7.7mmHg, mientras que en la presión arterial diastólica fue de 2.2mmHg, lo cual nos muestra que la diferencia no es significativa. La administración benzodiazepínico fue irrelevante en cuanto a la duración del acto quirúrgico y del estado general del paciente. Conclusión: El uso del benzodiazepínico (alprazolam de 0.25mg) mostró un resultado irrelevante.


Type of study: clinic experimental, random controlled double-blind and crossed type. Objective: determine if the prophylactic use of benzodiazepine improves the conditions in which the surgical procedures are carried out. Materials and methods: the effects of 20 dental extractions, which were conducted on controlled essentially hypertensive patients, were studied in order to analyze the variables: systolic and diastolic blood pressure, duration of the surgical act and general state of the patient. Results: when the highest increase of the systolic blood pressure of drug and placebo groups were observed, there was a difference of 7.7 mmHg, while the diastolic blood pressure was of 2.2.mmHg, which shows us that the difference is not significant. The administration of benzodiazepine was irrelevant concerning the duration of the surgical act and the general state of patient. Conclusion: the use of benzodiazepine (alprazolam 0.25 mg) showed an irrelevant result.


Subject(s)
Male , Adult , Female , Young Adult , Middle Aged , Benzodiazepines , Hypertension , Oral Surgical Procedures , Surgery, Oral , Arterial Pressure , Placebo Effect
9.
An. acad. bras. ciênc ; 80(2): 335-340, June 2008. ilus, graf
Article in English | LILACS | ID: lil-482888

ABSTRACT

The EEG has been widely employed in the assessment of electrophysiological changes induced by distinct medications. Its sensibility in detecting alterations produced by a specific substance may be enhanced by methods of quantitative analyses (qEEG). The present study aimed at investigating the modulatory effects of bromazepam on brain dynamics. The effects of bromazepam (3mg) on EEG power distribution were tested in 10 healthy individuals, in a double-blind experiment. The electrophysiological measure was analyzed across experimental conditions, moments, and electrodes, in the delta, theta, alpha and beta frequency bands separately. A significant decrease of relative power was observed in delta and theta (main effect of condition). No interactions were observed. Although the expected anxiolytic EEG profile was not observed (increased beta and decreased alpha activity), this specific result may be related to other factors such as dosage used and the subjects' general physiological state, and not necessarily to the drug itself.


O EEG tem sido amplamente empregado na avaliação de mudanças eletrofisiológicas induzidas por medicações distintas.A sensibilidade desta técnica em detectar alterações produzidas por uma substância pode ser aprimorada por métodos de análise quantitativa (EEGq). O presente estudo teve por objetivo investigar os efeitos modulatórios do bromazepam na dinâmica cerebral. Os efeitos de 3mg de bromazepam na distribuição de potência cortical foram observados em 10 indivíduos sadios, em um desenho duplo-cego. A medida eletrofisiológica foi analisada nas diferentes condições experimentais, momentos e eletrodos, em delta, teta, alfa e beta separadamente. Uma diminuição significativa de potência relativa foi observada em delta e teta (efeito principal para condição). Não foram observadas interações. Embora o perfil ansiolítico do EEG (aumento de beta e diminuição de alfa) não tenha sido observado, esteresultado específico pode estar relacionado a outros fatores, tais como dose utilizada e estado fisiológico dos sujeitos, e não necessariamente à droga propriamente dita.


Subject(s)
Adult , Female , Humans , Male , Anti-Anxiety Agents/pharmacology , Bromazepam/pharmacology , Electroencephalography/drug effects , Motor Cortex/drug effects , Analysis of Variance , Double-Blind Method , Motor Cortex/physiology
SELECTION OF CITATIONS
SEARCH DETAIL